Technical Details of SEFUSE®
SEFUSE® thermal links product table
There are two SEFUSE® types: SF and SM. The SF-type uses thermosensitive material as the thermal pellet, while the SM-type uses a fusible alloy. Both types are suitable for a wide range of applications.
SEFUSE® thermal links SF type - Ratings
* BEAB Certification Non-Renewal
BEAB certification, which had been obtained for some series of SEFUSE® thermal links, will not be renewed after the expiration date of February 2022.
* About CCC Self-Declaration number
Due to the publication of new implementation rules from the Certification and Accreditation Administration of the People’s Republic of China (CNCA), the authentication method of thermal links was changed to CCC Self-Declaration (Index No. 2019-1571296947171 / Document No. 2019 No. 44). SCHOTT SEFUSE® thermal links that had acquired CCC certification have completed the conversion to the CCC Self-Declaration accordingly.
* CCC Certification : Update GB/T9816.1-2023 Standard
The applicable standard of CCC certification for SEFUSE® thermal fuses has been updated to GB/T9816.1-2023.The self-declaration number remains unchanged.
Series | Old Certification No. | Self-Declaration No. |
---|---|---|
SF/R series |
2013010205600209 |
2020970205000025 |
SFH/R series | 2013010205613895 |
2020970205000045 |
SF/K series |
2008010205282881 |
2020970205000038 |
SF/Y series |
- |
2020000205000015 |
Note
- Except for SF265R, no use of hazardous substances prescribed by WEEE and RoHS. All products do not use SVHC prescribed by REACH (241 substances, 27th Jun, 2024).
-
- SF/R series & SFH/R series: For standard lead length type, add the suffix “0“ at the end of the part number. For long lead length type, add the suffix “1“ at the end of the part number.
- SF/Y series: Part number indicates thermal links with standard lead lengths. For long lead length types, add the suffix “-1” at the end of the part number.
- Th is the maximum temperature measured on the thermal link when it continues to conduct a rated current without changing its state of conductivity for 168 hours.
- The electrical ratings according to the various safety standards are shown in the following table.
-
Rated Voltage UL/cUL VDE CCC KTL PSE 6) AC120V 20A (Resistive) - - - - AC250V 10A (Resistive) 10A 10A 10A 10A 15A (Resistive) 15A 15A 15A 15A 16A (Resistive) - - - -
- SF/R series: The following SF-types have passed the Conductive Heat Aging Test (CHAT) specified by the UL safety standard: SF113R*, SF129R*, SF139R*, SF144R*, SF150R*, SF167R*, SF184R*, SF188R*, SF214R*, SF229R*, SF240R, and SF265R*.
- SFH/R series: The following SF-types have passed the Conductive Heat Aging Test (CHAT) specified by the UL safety standard: SFH124R*, SFH162R* and SFH172R*.
- SF/K series: The following SF-types have passed the Conductive Heat Aging Test (CHAT) specified by the UL safety standard: SF167K, SF188K and SF214K.
-
- SF/R series: With respect to the PSE standard, SF/R is separately available for 10 A and 15 A ratings. Please select the appropriate product rating according to the specifications of the final application.
- SFH/R series: With respect to the PSE standard, SFH/R is separately available for 10 A and 15 A ratings. Please select the appropriate product rating according to the specifications of the final application.
- In case of requests for 10 A rated current thermal links, please add “J1” after the part number (name). i.e. SF***R0 J1, SFH***R0 J1
- The following electrical ratings were used for the UL, VDE, and KTL safety standards: 10 A (Resistive)/AC 250V.
- Pending approval.
SEFUSE® thermal links SM type - Ratings
* BEAB Certification Non-Renewal
BEAB certification, which had been obtained for some series of SEFUSE® thermal links, will not be renewed after the expiration date of February 2022.
* About CCC Self-Declaration number
Due to the publication of new implementation rules from the Certification and Accreditation Administration of the People’s Republic of China (CNCA), the authentication method of thermal links was changed to CCC Self-Declaration (Index No. 2019-1571296947171 / Document No. 2019 No. 44). SCHOTT SEFUSE® thermal links that had acquired CCC certification have completed the conversion to the CCC Self-Declaration accordingly.
Series | Old Certification No. | Self-Declaration No. |
---|---|---|
SM/A series |
2002010205023067 |
2020970205000026 |
SM/B series | 2002010205023066 |
2020970205000019 |
SM/G series |
2012010205547628 |
2020970205000044 |
Note
- No use of hazardous substances prescribed by WEEE and RoHS. All products do not use SVHC prescribed by REACH (241 substances, 27th June, 2024).
- For standard lead length type, add the suffix “0” at the end of the part number. For long lead length type, add the suffix “1” at the end of the part number.
- DC ratings are approved by UL and VDE.
- SM072A* has c-UL recognition.